The VM-3240E is a multifunctional amplifier that can be mounted in an EIA-Standard equipment rack (3-unit size). The unit comes with the speaker output section which has an internal attenuator and 6-output selector. In addition, the unit features the surveillance function which automatically checks the system for failures.

Features:

·         Expansion unit for VM-3000 System management amplifier, up to 9 extensions possible

·         240 W rated output.

·         6 speaker line outputs

·         For BGM: output selection with volume control on front panel

·         8 control inputs and 8 control outputs for general purpose

·         6 control inputs for emergency purpose and 3 control outputs for status information

Specifications

VM-3240E

VM-3360E

Power source

230 V AC, 50 / 60 Hz 24 V DC

230 V AC, 50 / 60 Hz 24 V DC

Rated output

240 W total into 6 zones

360 W total into 6 zones

Frequency response

50 Hz - 20 kHz

50 Hz - 20 kHz

Distortion

< 0.7 %

< 0.7 %

Power / current consumption

600 W (with rated output signal), 260 W (according to EN 60065)

850 W (with rated output signal),

380 W (according to EN 60065)

S/N ratio

85 dB(A) (or more)

85 dB(A) (or more)

Inputs

External amplifier Input: 100 V Line removable terminal block (14 pins)

Local input -50 dBV (Mic) / -10 dBV (Line), 600 Ω / electronically balanced, removable terminal block (14 x 2 pins)

External amplifier Input: 100 V Line removable terminal block (14 pins)

Local input -50 dBV (Mic) / -10 dBV (Line), 600 Ω / electronically balanced, removable terminal block (14 x 2 pins)

Outputs

Speaker output 1 - 6: Total within rated output, removable terminal block (14 pins)

Direct output from internal or external amplifier, removable terminal block (16 pins)

Speaker output 1 - 6: Total within rated output, removable terminal block (14 pins)

Direct output from internal or external amplifier, removable terminal block (16 pins)

Control input

Input 1 - 8: No-Voltage make contact input, open voltage: 24 V DC, short-circuit current: under 2 mA, removable terminal block (14 pins)

Input 1 - 8: No-Voltage make contact input, open voltage: 24 V DC, short-circuit current: under 2 mA, removable terminal block (14 pins)

Control output

Output 1 – 8: Isolated open collector output, withstand voltage: 30 V DC, operating current: under 10 mA, removable terminal block (14 pins)

Output 1 – 8: Isolated open collector output, withstand voltage: 30 V DC, operating current: under 10 mA, removable terminal block (14 pins)

Indicator

Power; 5-segment bargraph level meter, selected zone, emergency zone active, communication fault, CPU fault

Power; 5-segment bargraph level meter, selected zone, emergency zone active, communication fault, CPU fault

Operating temperature

-5°C to +45°C

-5°C to +45°C

Operating humidity.

5 to 95% RH (no condensation)

5 to 95% RH (no condensation)

Dimensions

482 x 132.6 x 407 mm (W x H x D)

482 x 132.6 x 407 mm (W x H x D)

Finish

Aluminium, Steel plate, black

Aluminium, Steel plate, black

Accessory (included)

AC power cord (2 m) x 1, plastic foot x 4, plastic foot mounting screw x 4, removable terminal plug (14 pins) x 3, removable terminal plug (16 pins) x 1, link cable (3 m) x 2

AC power cord (2 m) x 1, plastic foot x 4, plastic foot mounting screw x 4, removable terminal plug (14 pins) x 3, removable terminal plug (16 pins) x 1, link cable (3 m) x 2